The general-purpose dry-type transformer is the highly adaptable cornerstone of modern power distribution. Engineered strictly to IEC and national standards, it utilizes high-strength vacuum-cast epoxy resin and optimized low-noise configurations. It flawlessly merges the oil-free, eco-friendly, and zero-fire-risk benefits of dry-type equipment with universal adaptability across multiple industries. With Tier 2 energy efficiency (NX2), it is the most reliable, cost-effective choice for large-to-medium substations, industrial plant upgrades, commercial high-rises, and renewable energy integration projects.
Core Parameters:
• Energy Efficiency: Tier 2 Efficiency (SCB10 Series, GB 20052-2024 NX2).
• Structure: Solid Resin Cast Insulation + Highly Adaptable Compact Footprint.
• Cooling Mode: AN / AF Dual Mode (Forced air safely boosts capacity by up to 30%).
Product Features

Designed with highly customizable high-voltage taps and compact dimensions, allowing it to seamlessly replace older units across virtually any industrial or commercial sector.

100% oil-free design using premium flame-retardant epoxy resin. It acts as a self-extinguishing barrier, eliminating all explosion hazards in densely populated indoor spaces.

Adheres to the SCB10 Tier 2 efficiency standards (NX2). It slashes losses by 20%~40% compared to legacy setups, striking the perfect balance between capital investment and energy savings.

Features a high-grade silicon steel core assembled with 45° step-lap joints. This drastically dampens magnetic vibration, keeping noise levels exceptionally low for quiet environments.

Standardly relies on Natural Air (AN) cooling. Activating the optional Forced Air (AF) cooling can safely boost the operational capacity by up to 30% during peak demand periods.

With no insulating oil to monitor or replace, operational maintenance is reduced to simple visual checks and occasional fan dust wiping, perfect for semi-unattended grid nodes.
Key Specifications (General-Purpose SCB10 Series)
| Parameter | Typical Value | Description |
| Energy Efficiency | Tier 2 (GB 20052-2024 NX2) | The standard for budget-conscious, highly stable universal distribution grids. |
| Rated Voltage | HV: 10kV / 35kV LV: 0.4kV | Highly precise three-phase distribution output to directly power commercial and industrial hubs. |
| Vector Group | Dyn11 | Standard connection ensuring robust handling of severe unbalanced electrical loads. |
| No-Load Loss | Approx. 0.18kW ~ 4.3kW | Reliably low idle energy waste through high-grade silicon steel construction. |
| Load Loss (120℃) | Approx. 1.2kW ~ 24.0kW | Stable energy conversion efficiency under continuous distribution loads. |
| Protection Structure | IP00 (Open) / IP20 (Enclosed) | Highly adaptable; open for clean rooms, enclosed for shared commercial basements. |
Full Series Technical Reference (SCB10 Platform: 30kVA ~ 3150kVA)
| Capacity (kVA) | Impedance (%) | No-Load Loss (W) | Load Loss (W) | Total Weight (kg) | Dimensions W×D×H (mm) |
| 30 | 4.0 | 180 | 600 | 250 | 800×600×900 |
| 50 | 4.0 | 240 | 870 | 320 | 850×650×950 |
| 100 | 4.0 | 380 | 1500 | 550 | 950×700×1000 |
| 160 | 4.0 | 540 | 2000 | 750 | 1050×750×1050 |
| 200 | 4.0 | 620 | 2400 | 880 | 1100×800×1100 |
| 250 | 4.0 | 720 | 2800 | 1050 | 1150×800×1150 |
| 315 | 4.0 | 880 | 3400 | 1250 | 1200×850×1200 |
| 400 | 4.0 | 980 | 4100 | 1450 | 1250×900×1250 |
| 500 | 4.0 | 1160 | 4900 | 1700 | 1300×950×1300 |
| 630 | 4.5 | 1340 | 6200 | 1950 | 1350×1000×1350 |
| 800 | 4.5 | 1520 | 7500 | 2300 | 1400×1000×1400 |
| 1000 | 4.5 | 1770 | 8800 | 2700 | 1450×1050×1450 |
| 1250 | 4.5 | 2090 | 10800 | 3200 | 1550×1100×1550 |
| 1600 | 4.5 | 2450 | 13200 | 3800 | 1650×1150×1650 |
| 2000 | 4.5 | 3000 | 16000 | 4500 | 1750×1250×1800 |
| 2500 | 4.5 | 3600 | 19500 | 5300 | 1850×1300×1900 |
| 3150 | 4.5 | 4300 | 24000 | 6500 | 2000×1400×2100 |
* The table above displays the complete parameter range for the universal SCB10 platform. Dimensions and weights serve as a precise reference for electrical room space planning. Protective enclosures (IP20/IP40) will add slight variations.
FAQ
To ensure maximum lifespan and capacity out of your general-purpose dry-type transformer, follow these critical indoor installation guidelines:
1) Ventilation & Clearances: Dry-type transformers rely entirely on ambient air to shed heat. You must maintain a minimum clearance of 0.8m to 1.0m from the walls and surrounding switchgears to ensure smooth natural air convection (AN mode). For larger models utilizing forced air (AF), ensure fan intakes are unobstructed.
2) Room Exhaust Systems: The electrical room cannot be fully sealed. It must have adequate louvers for natural cross-ventilation. For high-capacity units (≥800kVA), the room must be equipped with active exhaust fans placed near the ceiling to expel the rising hot air, keeping the ambient room temperature strictly below 40℃.
3) Proper Enclosure Selection: If the electrical room is clean, secure, and restricted to qualified personnel, an open unit (IP00) provides the best cooling. If the room is shared, dusty, or has rodent risks, you must order the transformer with an IP20 (standard mesh) or IP40 (solid metal) protective enclosure, ensuring the cable entry ports are properly sealed post-installation.
General dry type electrical transformers use air for cooling without flammable insulating oil. They feature low fire risk, small pollution and simple maintenance. They can be installed indoors, close to load points. They have stable performance and strong resistance to humidity and dust, widely used in commercial buildings, hospitals and subway power supply systems.
Our general dry type electrical transformers adopt high-quality epoxy resin insulation materials. The windings are cast integrally under vacuum condition. This structure helps reduce partial discharge and improve mechanical strength. The material is flame-retardant and anti-cracking, which can adapt to different ambient temperatures and ensure long-term stable operation under normal working conditions.
General dry type electrical transformers are suitable for working environments with ambient temperature between -20℃ and +40℃. The altitude of the installation site should not exceed 1000 meters. The site shall keep good ventilation and avoid corrosive gas, conductive dust and heavy vibration. If working beyond these limits, parameter adjustment is needed before order confirmation.
Yes, we can customize general dry type electrical transformers on voltage ratio, rated capacity and tapping range according to customer’s power project demands. We also support different protection casing options. Customers need to provide detailed parameters such as load type, working frequency and installation condition, so we can confirm the most suitable transformer design scheme.