Social Media
The 1000 kva dry type transformer is a highly reliable and efficient power distribution solution designed for commercial and industrial applications. Unlike oil-filled alternatives, the 1000 kva dry type transformer uses air as the cooling medium, eliminating fire hazards and environmental contamination risks. It features excellent insulation performance, low noise operation, and minimal maintenance requirements, making it ideal for indoor installations such as hospitals, schools, and data centers. With a compact design and superior overload capacity, the 1000 kva dry type transformer ensures stable voltage output and long service life, delivering outstanding value for modern electrical systems.
Core Parameters:
• Energy Efficiency: Tier 2 Efficiency (Complies with GB 20052-2024).
• Structure: Enhanced Resin Cast Insulation + AN/AF Dual Cooling.
• Warranty: 3-Year Standard Warranty (covers core components).
Product Features

Fully oil-free enhanced resin-cast operation. Inherently flame retardant and self-extinguishing, utterly eradicating explosion hazards in highly populated commercial and industrial areas.

Meets Tier 2 efficiency. Large-section copper windings drastically reduce resistance losses. The solid resin structure naturally resists moisture and dust, yielding a design lifespan of 25+ years.

Equipped with comprehensive smart protection including temp controllers and surge protection devices. The fully enclosed thick enclosure guarantees stability in complex indoor or semi-outdoor setups.

Modular design accommodates indoor floor installation or outdoor pre-installed layouts without building dedicated oil pits. Features a robust 1.2x short-term overload capacity for peak reliability.

No oil testing or replacement required. Regular dust wiping of cooling channels and visual checks on the winding insulation state are all that's needed for a 1000 kva dry type transformer, keeping O&M costs exceptionally low.

The 1000 kva dry type transformer can be fitted with a smart monitoring system to remotely track winding temperatures, load currents, and insulation status, supporting fault warnings and minimizing manual patrols.
Key Specifications (1000kVA dry type transformer SCB13 Series)
| Parameter | Typical Value | Description |
| Rated Capacity | 1000kVA | Reliable apparent power perfectly tailored for large commercial complexes and industrial park centers. |
| Rated Voltage | HV: 10kV | LV: 0.4kV | Standard grid voltages, highly adaptable for varied regional distribution systems. |
| Vector Group | Dyn11 / Yyn0 | Mainstream connections ensuring seamless integration and balanced load supply. |
| Impedance | 4.5% ~ 6.0% | Effectively limits short-circuit currents, protecting downstream distribution equipment. |
| No-Load Loss | ≤ 1.15kW (SCB13) | Tier 2 compliant; ultra-low idle consumption significantly reduces electricity overhead. |
| Load Loss (120℃) | ≤ 8.60kW | Copper windings ensure minimal resistance, maximizing energy conversion under load. |
| Winding Temp. Rise | ≤ 100K (Class F) | Resin insulation and robust air convection prevent heat-induced insulation degradation. |
| Noise Level | ≤ 50~55dB(A) | Shock-absorbing design creates an ultra-quiet footprint, avoiding noise pollution. |
| Cooling Method | AN / AF (Dual Mode) | Natural air handles standard loads; Forced air (AF) safely boosts load capacity by an extra 30%. |
Detailed Description
The 1000kVA cast-resin dry-type transformer (mainstream SCB13 series) is a three-phase, Tier 2 efficiency unit recognized as a premier choice for medium-large capacity distribution. Its defining advantage is absolute environmental safety combined with a strong load-bearing structure. Utilizing a solid epoxy resin cast, it blocks out moisture and dust while delivering unmatched flame-retardant properties—eliminating the severe fire and leakage risks associated with oil-immersed alternatives.
Engineered with large-section copper windings and an advanced dual-mode air convection cooling system, this dry type transformer achieves highly stable, low-loss operation. Operating smoothly across -25℃ to 40℃, it exhibits exceptional overload capabilities, supported by optional forced-air cooling that surges capacity by 30%. Because of its modular design and ultra-quiet performance, the dry type transformer is widely deployed in highly sensitive zones such as commercial complexes, data centers, and precision industrial main stations.
SCB10 Type Parameters & Scenarios
| Parameter | Typical Value | Description |
| Energy Efficiency | GB 20052-2024 Tier 2 (NX2) | Adapts to basic energy-saving compliance requirements. |
| No-Load Loss | Approx. 1.30kW | Slightly higher than SCB13, fulfilling fundamental medium-voltage needs. |
| Load Loss (120℃) | Approx. 9.60kW | Consistent with the SCB13 model of the same capacity under load. |
| Partial Discharge | ≤ 10pC | Reliable insulation performance, ensuring foundational operational safety. |
| Core Material | Standard High-Grade Silicon Steel | Balances magnetic permeability and cost for conventional operations. |
| Applicable Scenarios | Budget-limited, load ≤ 60% | Ideal for standard commercial blocks, small manufacturing hubs, and older grid upgrades. |
Standard SCB13 Series Technical Reference
| Capacity (kVA) | Impedance (%) | No-Load Loss (W) | Load Loss (W) | Total Weight (kg) | Dimensions W×D×H (mm) |
| 500 | 4.0 | 680 | 4800 | 1700 | 1300×950×1300 |
| 630 | 4.5 | 810 | 5880 | 1950 | 1350×1000×1350 |
| 800 | 4.5 | 980 | 7100 | 2300 | 1400×1000×1400 |
| 1000 | 4.5 | 1150 | 8600 | 2700 | 1450×1050×1450 |
| 1250 | 4.5 | 1350 | 10400 | 3200 | 1550×1100×1550 |
| 1600 | 4.5 | 1650 | 12800 | 3800 | 1650×1150×1650 |
* The table displays standard SCB13 dry-type technology platform parameters. Dimensions and weights are for reference and may vary based on specific enclosure customizations.
FAQ
Installing a 1000kVA dry-type transformer requires focusing on structural handling, expanded layout adaptation, and adequate ventilation. Core precautions include:
1) Installation Layout Adaptation: Maintain a safe distance of ≥1.5m from surrounding electrical equipment and cables. Reserve a broader maintenance channel of ≥1.0m to ensure safe operational space for this larger footprint.
2) Cooling Space Reservation: Ensure a clearance of ≥1.2m above the unit and ≥0.8m around the sides. Do not install in completely sealed spaces. Natural airflow must be unobstructed. If using the AF (forced air) cooling mode, the room must be equipped with adequate ventilation ducts.
3) Power Match & Grounding: Ensure the input/output voltages strictly match the 10kV grid. The enclosure and core must be reliably grounded with a resistance of ≤4Ω to provide uncompromised leakage protection.
4) Handling & Flexible Mounting: This unit is heavy (approx. 2700kg). It must be handled using dedicated lifting gear or heavy-duty forklifts, ensuring no bumps occur to the resin windings. For floor installation, the ground must be flat and solid, utilizing robust standard brackets. Tilting can impair both insulation and cooling performance.

Whatsapp: +86-13961294414
E-mail: junqiu.wang@czguanghui.cn
jocelyn.duan@czguanghui.cn
ADD: No. 1, Yulong Middle Road, Xuejia Town, Xinbei District, Changzhou City, China